A Guide to Performing the Schirmer Tear Test: Equipment and Step-by-Step Procedure

Schirmer Tear Test equipment

The Schirmer Tear Test is a diagnostic test used to evaluate the quantity of tear production in the eyes

The Schirmer Tear Test is a diagnostic test used to evaluate the quantity of tear production in the eyes. It is commonly used in ophthalmology and veterinary medicine to diagnose conditions such as dry eye syndrome and lacrimal gland dysfunction.

To perform the Schirmer Tear Test, specific equipment is required. Here are the basic components of the test kit:

1. Schirmer Tear Test Strips: These are small, absorbent paper strips typically measuring about 5 mm in width and 35 mm in length. They are divided into three sections: a dry section, a section marked with a standardized scale, and a portion that remains outside the eye for easy handling.

2. Aseptic Forceps: These are used to hold the test strip securely during the test, avoiding any contamination and ensuring precision.

3. Topical Anesthetic: A mild anesthetic is usually applied to the surface of the eye to minimize any discomfort experienced by the patient.

4. Vernier Calipers or Measurement Ruler: These tools are used to measure the amount of wetting on the tear test strip accurately. Vernier calipers provide a more precise measurement, while a measurement ruler can be used for a more general estimation.

5. Light Source: A well-lit examination room is necessary to ensure clear visibility during the test. A bright light source such as an examination lamp or a slit lamp is commonly used.

Here is a step-by-step guide on how to perform the Schirmer Tear Test using the equipment mentioned above:

1. Explain the procedure to the patient or owner and obtain informed consent.

2. Measure and record the baseline length of the Schirmer Tear Test strip using vernier calipers or a measurement ruler. This is the starting point to assess tear production accurately.

3. Apply a drop of topical anesthetic to the surface of the eye, usually using a sterile dropper or ophthalmic eye solution.

4. Gently grasp the test strip with aseptic forceps, ensuring that the dry section is held securely.

5. Place the bent tip of the test strip inside the lower conjunctival sac, at the junction of the middle and lateral thirds of the lower eyelid.

6. Instruct the patient or owner to keep their eyes gently closed to minimize evaporation of tears during the test, but not to squeeze or rub their eyes.

7. Allow the test strip to remain in place for a specific duration (usually 5 minutes). Note that some variations of the Schirmer Tear Test require shorter or longer durations, so it’s essential to refer to the specific protocol you are following.

8. After the designated time, carefully remove the test strip using the aseptic forceps, ensuring the tear-soaked portion is undisturbed and intact.

9. Use the vernier calipers or measurement ruler to precisely measure the tear-soaked portion of the test strip.

10. Record the tear production measurement and compare it to the reference scale on the test strip to assess normal or abnormal tear production.

11. Repeat the test for the other eye if necessary.

Remember, it is important to follow proper hygiene protocols, maintain a calm and reassuring environment, and ensure the equipment is sterile to maintain accuracy in the results and the comfort of the patient.

More Answers:

Understanding Tonometry: The Procedure and Importance in Diagnosing and Managing Eye Conditions
Optimizing Tear Production Assessment: Essential Techniques and Precautions for Accurate Schirmer Tear Test Results
The Importance of Understanding Tear Production and Factors that Influence it